Cookies auf den Omega Webseiten Wir verwenden Cookies auf unserer Webseite. Diese Cookies sind für die ordnungsgemäße Funktion der Webseite unerlässlich. Wenn Sie fortfahren, ohne Ihre Einstellungen zu ändern, gehen wir davon aus, dass Sie alle Cookies auf dieser Webseite akzeptieren.Um weitere Informationen zu diesen Cookies zu erhalten, klicken Sie bitte hier.
Application
• The DRST-CM detachable display adds Modbus RTU RS-485 serial communications to all current and future DRST Series units.
• The unit converts a wide array of sensors and analog device signals measured by the system like uni- and bipolar mA and voltage signals, potentiometer, Lin. R, RTD and TC, to a Modbus communication line signal.
• All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by using the front display menu.
• The easily readable DRST-CM display can be used to read the process signal, simulate the output signal, indicate sensor errors and internal device errors.
Technical Characteristics
• DRST-CM has full DRSL-Display functionality for unit programming, process signal monitoring and diagnostics handling.
• Modbus RTU protocol is supported using a serial RS-485 communication wiring.
• Multi-drop half-duplex connection via shielded RJ45 connector.
• High safe galvanic isolation of 2.5 kVAC between the serial wiring and the connected system DRST units.
• Modbus parameters such as address, baud rate, stop bit(s), and parity bit are configured from the DRST-CM display, which also stores parameters.
Mounting/Installation/Programming
• Mounting in Zone 2 / Div 2. This DRST-CM can be moved from one device to another. The individual system DRST unit configuration of the first device can be saved and downloaded to subsequent devices.
• Programmed parameters can be protected by a user defined password.
• When mounted on devices that are installed upside down, a menu item allows the display on DRST-CM to be rotated 180o and the up/down buttons to switch function.
Specifications Environmental Conditions Operating Temperature: -20 to 60°C Storage Temperature: -20 to 85°C Relative Humidity: < 95% RH (non-cond.) Protection Degree: IP20 Installation In: Pollution degree 2 and measurement/overvoltage cat. II Mechanical Specifications Dimensions (HxWxD): 73.2 x 23.3 x 26.5 mm Dimensions (HxWxD) w/4000/9000 Unit: 109 x 23.5 x 131 mm Weight Approx: 100 g Connection: RJ45 - shielded Common Specifications Supply Max. Required Power: = 0.15 W Isolation Voltage Isolation Voltage, Test/Working: 2.5 kVac/250 Vac reinforced isolation Response Time Response Time: < 20 ms Signal/Noise Ratio: > 60 dB Update Rate: > 50 Hz Extended EMC Immunity: NAMUR NE21, A Criterion, Burst: No loss of communication Signal Type: RS485 half duplex Serial Protocol: Modbus RTU Modbus Mode: RTU - slave Devices on an RS485 Line:Up to 32 (without a repeater) Data Rates, Baud: 2400, 4800, 9600, 19200, 38400, 57600, 115200 Automatic Baudrate Detection: Yes - can be configured ON or OFF Parity: Even, Odd, None Stop Bit(s): 1 or 2 Digital Addressing: 1 to 247 Response Delay:0 to 1000 ms Observed Authority Requirements EMC: 2014/30/EU LVD: 2014/35/EU EAC TR-CU 020/2011 Approvals DNV-GL Marine: Stand. f. Certific. No. 2.4 ATEX 2014/34/EU: DEKRA 13ATEX0098 X IECEx: DEK 13.0026 X FM: 0003049132-C UL: UL 61010-1