Cookies auf den Omega Webseiten Wir verwenden Cookies auf unserer Webseite. Diese Cookies sind für die ordnungsgemäße Funktion der Webseite unerlässlich. Wenn Sie fortfahren, ohne Ihre Einstellungen zu ändern, gehen wir davon aus, dass Sie alle Cookies auf dieser Webseite akzeptieren.Um weitere Informationen zu diesen Cookies zu erhalten, klicken Sie bitte hier.
OMEGA™ FMA-7000E Mass Flow Controllers accurately measure gases on the basis of mass flow. The flow sensor produces an electrical output signal linear with the flowrate used for indicating, recording, and/or control purposes. It eliminates the need for continuous monitoring and readjustment of gas pressures to provide a stable gas flow. This is accomplished automatically by an electromagnetically actuated flowrate control valve.
OPERATING PRINCIPLE The operating principle of the controller is thermodynamic. A precision power supply directs heat to the midpoint of the sensor tube carrying the flow. On the same tube, equidistant upstream and downstream of the heat input, are resistance temperature measuring elements. With no flow, the heat reaching each temperature element is equal. With increasing flow, the flow stream carries heat away from the upstream element, and carries it towards the downstream element. An increasing temperature difference develops between the two elements and this difference is proportional to the mass flowrate of the gas. A bridge circuit interprets the temperature difference and an amplifier provides the output to the control circuitry as well as a 0-5 Vdc output signal.
SPECIFICATIONS Accuracy: ±1% FS including linearity at calibration conditions, ±1.5% FS including linearity for flow ranges greater than 20 SLM Repeatability: ±0.25% of rate Response Time: <3 second response to within 2% FS final value with a 0 to 100% command step Set Point Input: 0 to 5 Vdc or 1000Ω potentiometer Output: 0 to 5 Vdc into 2000Ω minimum load; 3 mV rms max. ripple Maximum Pressure: 1500 psig (Note: Additional charge for pressures >999 PSI). Pressure drop 5 to 50 psid Temperature Range: 4 to 66°C(40 to 150°F) ambient and gas Temp. Sensitivity: Zero: < ±0.075% FS per °C Span: <±1.0% FS shift over 10 to 50°C (50 to 122°F) range Power Supply Sensitivity: ±0.09% FS per % power supply voltage variation Mounting Attitude Sensitivity: ±0.5% maximum FS deviation after zeroing Leak Integrity: 1 x 10-9 Atm. scc/sec helium Control Range: 50 to 1 Pressure Sensitivity: ±0.03% per psi up to 200 psig (N2) Power: +15 Vdc at 35 mA DC, -15 Vdc at 180 mA dc, 3.5 watts power consumption Wetted Parts: 316 and 430SS, FKM Connections: ¼" stainless steel compression fittings Electrical Connections: Card edge, 20 terminals, gold over low stress nickel-plated copper Accessories Included: Mating connector with 1.5 m (5') ribbon cable model. Easy connector/cable assemblies available
Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.
Bestellung nach Modellnummer
*Alle Preisangaben in Euro. Anmerkung: Comes complete with connector and operator's manual.
Specifiy inlet/outlet pressures in order comments. For set-up/calibrations involving pressures over 999 PSI add £375 to the price.
Calibrations done at ambient (20C/70F) temperature only.
All models are custom, consult specification page for a complete product description and list of available models.
We noticed you are from the US. Visit your local site for regional offers and live support.