Beschreibung
The Cutler-Hammer® MVX9000 Series sensorless vector adjustable frequency AC Drives from Eaton’s electrical business are designed to provide adjustable speed control of 3-phase motors. These microprocessor-based, sensorless vector drives have standard features that can be programmed to tailor the drive’s performance to suit a wide variety of application requirements. The MVX9000 sensorless vector series utilizes a 32-bit microprocessor and insulated gate bipolar transistor (IGBTs) which provides quiet motor operation, high motor efficiency and smooth low speed performance. The size and simplicity of the MVX9000 Series makes it ideal for hassle free installation where size is a primary concern. Models rated at 480V, 3-phase, 50/60 Hz are available in sizes ranging from 1 to 10 hp. Models rated at 240V, single- or 3-phase, 50/60 Hz are available in sizes ranging from 0.5 to 7½ hp. Models rated at 115V, single-phase, 50/60 Hz are available in the ¼ to 1 hp size range. The standard drive includes a digital display, operating and programming keys on a removable keypad. The display provides drive monitoring as well as adjustment and diagnostic information. The keys are utilized for digital adjustment and programming of the drive and for operator control. Separate terminal blocks for control and power wiring are provided for customer connections. Other features provided as standard include built-in DC braking, RS485 serial communications and PID control.SPECIFICATIONS | ||
OUTPUT RATINGS
Horsepower: 90 to 132V, 1/4 to 1 hp 200 to 240V: 1/2 to 71/2 hp 380 to 480V: 1 to 10 hp 425 to 660V: 1 to 10 hp Frequency Range: 0.1 to 400 Hz Overload Rating: 150% for 60 sec Frequency Resolution: Digital: 0.1 Hz Analog: Max (set frequency/1000) Hz Frequency Accuracy: Digital: ±0.01% of max frequency Analog: ±0.2% of max frequency Undervoltage Carryover Limit: 0.3 to 25 sec MOTOR PERFORMANCE Motor Control: Sensorless vector Constant and Variable Torque: Standard Speed Regulation: 0.5% of base speed INPUT POWER Voltage: 50/60 Hz ±3 Hz 100 to 120V: -10% +10%/1-phase 200 to 240V: -10% +5%/1-phase 200 to 240V: -10% +5%/3-phase 380 to 480V: -10% +10%/3-phase 500 to 600V: -15% +10%/3-phase Displacement Power Factor: Better than 0.95 Efficiency: Typically greater than 95% DESIGN TYPE Microprocessor: 32-Bit Converter Type: Diode Inverter Type: Insulated gate bipolar transistor Waveform: Sensorless vector ENVIRONMENT Operating Temperature: -10 to 50°C (14 to 122ºF), -10 to 40°C (14 to 104ºF); above 71/2 hp) Humidity: 20 to 90%, non-condensing Max Elevation: 1000 m (3281') Codes and Standards: NEMA, IEEE, NEC, design standards, UL Listed, cUL listed, CE marked (requires EMI filter) Enclosure: Standard, protected chassis (IP20) PROTECTIVE FEATURES Ground Fault: Standard Overload Protection: Standard Overcurrent: Standard Overvoltage: Standard Undervoltage: Standard Overtemperature: Standard Overload Limit: Standard |
SET UP ADJUSTMENTS, PERFORMANCE FEATURES, OPERATOR CONTROL AND EXTERNAL INTERFACE KEYPAD
Alphanumeric Display: Standard, 1 x 4 character Digital Indications: Frequency (Hz), Motor Current (amps), User-Defined RUN/STOP, FORWARD/REVERSE and parameters Diagnostics: Last 3 trips with cause LED Status Indicators: 8; RUN/STOP, FORWARD/REVERSE, Hz, amps, user defined, and input speed Operator Functions: START/STOP, speed control (digital or potentiometer), RESET, SETUP keys and ENTER I/O TERMINAL BLOCK Analog Inputs: 2 Inputs; 0 to 10 Vdc, 4 to 20 mA Potentiometer: 1 to 2K Analog Voltage: Nominal 10 Vdc, 10K input impedance Analog Current: Nominal 4 to 20 mA 250 Digital Inputs: 6 programmable inputs Digital Outputs: 1 programmable open collector and 1 form C relay contact Analog Monitor Output: Analog meter; frequency or output current dynamic brake chopper PROGRAMMABLE PARAMETERS Out of the Box: Factory settings loaded for quick start-up Accel. and Decel.: 2 separately adjustable linear or S curve times; 0.1 to 3000 sec Auto Restart: Overcurrent, overvoltage and undervoltage with 4 selectable retry restart modes DC Injection Braking: External Fault: Terminal input Jog: Terminal input Fault Reset: STOP/RESET or terminal input I/O: NO/NC Selectable Jump Frequencies: 3; with adjustable width Parameter Security: Programmable software lock Preset Speeds: 7 preset speeds PID Controller: PID process control Reversing: Keypad or terminal Speed Setting: Keypad, terminal or pot START/STOP Control: Keypad or terminal Stop Modes: Decel, coast or DC injection RELIABILITY Pretested Components: Standard Surface Mount Technology: Standard(PCBs) Computerized Testing: Standard Final Test with Full Load: Standard Eaton's Cutler-Hammer Engineering Systems and Service: National network of AF drive specialists |
DESCRIPTION HORSEPOWER | VOLTS | DIMENSIONS IN MM(IN) | SHIPPING WEIGHT KG(LBS) | ||
---|---|---|---|---|---|
WIDTH | HEIGHT | DEPTH | |||
¼ to 1 | 100 - 120 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
½ to 2 | 200 - 240 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
3 to 7½ | 200 - 240 | 125 (4.9) | 220 (8.6) | 193 (7.6) | 5.5 (12.1) |
1 to 3 | 380 - 480 | 100 (3.9) | 151 (5.9) | 145 (5.7) | 2.8 (6.2) |
5 to 10 | 380 - 480 | 125 (4.9) | 220 (8.6) | 193 (7.6) | 5.5 (12.1) |